DISASSEMBLY AND ASSEMBLY
ELEC
400
4.11 ELEC
4.11.1 SENSOR HUM & TEMP
REMOVAL
1.
Remove COVER ASSY RH.
2.
Disconnect connector (P/J104) from SENSOR HUM & TEMP.
3.
Remove the screw (silver, with flange, tapping, 8 mm) fastening SENSOR HUM
& TEMP to the main unit.
& TEMP to the main unit.
4.
Remove SENSOR HUM & TEMP from the main unit.
REINSTALLATION
1.
Attach SENSOR HUM & TEMP to the main unit.
2.
Fasten SENSOR HUM & TEMP to the main unit with the screw (silver, with
flange, tapping, 8 mm).
flange, tapping, 8 mm).
3.
Connect the connector (P/J104) to SENSOR HUM & TEMP.
4.
Attach COVER ASSY RH.
Figure 4-106. Removal of SENSOR HUM & TEMP
Table 4-6. Symptoms when the connector is loose
Connector
No.
Panel Indication
Symptom
Error Caused by Connector
Disconnection
P/J104
Service Req E530
Printing is not
possible.
Sensor HUM & TEMP error
Leg_Sec03_107EA