Epson TM-P60 Manuel D’Utilisation

Page de 142
4-2
   Application Development Information
Rev. D
4.1.3  Operation tested Access point products
The Access points that have been evaluated with the TM-P60 are in the following table. For the 
latest information, see the appropriate web site below:
For customers from North America, go to the following web site: http://pos.epson.com/
For customers from other countries, go to the following web site: http://www.epson-pos.com/
Select the product name from the “Select any product” pull down menu.
.
4.2  About the Battery Remaining Amount
4.2.1  The battery remaining amount
This printer has a battery to supply power. The battery has four statuses:
*When an AC adapter is connected to the printer, the “battery LED condition” is always Off.
4.2.2  The method to confirm the battery status
The battery status can be confirmed by every control method.
Vendor
Model
A/P firmware
RF firmware
Power Managiment 
funtion with TM-P60
Symbol
AP-4121-1150-US
0.252-13
V2.51-08
Impossible
Symbol
AP-4131-1050-WW
0.350-33
F3.10-04
Possible
Vender
Model
Software Ver.
Boot ver.
Power Managiment 
funtion with TM-P60
Cisco
Air-AP1120B-A-K9
12.2 (13)JA1
12.2(8)JA
Impossible
Battery Status
The battery
LED condition
Description
Level H (High)
Off
The remaining battery charge is between 100% and approximately 
50% when the amount of difference between the full battery and 
level L is 100%.
Level M 
(Medium)
Flashing
The remaining battery charge is between approximately 50% and 
level L when the amount of difference between the full battery and 
level L is 100%.
Level L (low)
On
The battery needs to be replaced or recharged because the 
remaining battery charge is low.
Level S (Serious)
On
The printer will not operate because the remaining battery charge 
is too low.