Pelco cm6800-322x6 Manuel D’Utilisation

Page de 80
C1522M-C (2/05)
47
MACRO
Macros simplify operator control by grouping multiple functions into a single command.
Figure 37.  Access the Macro Screen
MACRO:
Select the macro number you want to program.
STP:
Each macro can include up to 72 steps. For each step select entries for the following fields as necessary:
CMD:
Select a command. In addition, enter a valid number in the specified additional field(s); for example, if you
select PATT, enter a pattern number in the Command # field, a camera number in the Camera field, and a
monitor number in the Monitor field.
Refer to Table H in the 
Appendix for a description of each command and the additional fields required for each
command.
##:
If applicable, enter a valid number associated with the command selected.
CAM:
If applicable, enter a logical camera number. To select logical numbers other than the default numbers (1 to 32),
you must first program the logical numbering in the Logical Camera window. Refer to the 
Logical Camera
Numbers section.
MON:
If applicable, enter a monitor number.
DWL:
If desired, enter a dwell time (1-99 seconds); the dwell time is the period the macro halts before continuing to
the next step. The default dwell time is two seconds.
MACRO STATUS VIEW SCREEN
The Macro Status View screen provides a status view of each system macro (1-32). For each active macro the current status (RUN or
HOLD) and the number of the next macro step is displayed. If a macro is not running, the status is IDLE and the step number is 00.
A system operator can display the Macro Status View screen without entering password- protected programming screens.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1
CAMERA
2
LOGICAL CAMERA
3
MONITOR
4
ACCESS
5
TIME & DATE
6
PORT
7
PRIORITY
8
SEQUENCE
9
MACRO
10
ALARM CONTACTS
11
EVENT TIMER
12
SET AUXILIARY
13
SET PASSWORD
14
ABOUT CM6800
ENGLISH
RETURN
00654
MACRO MENU
MACRO 01
HELP
STP CMD
##
CAM
MON DWL
01
SWT
000
0001
01
01
02
SWT
000
0002
02
02
03
SWT
000
0003
03
03
04
SWT
000
0004
04
04
05
PRES
001
0005
08
01
06
— — — —
000
0006
00
01
07
— — — —
000
0007
00
01
08
— — — —
000
0008
00
01
09
— — — —
000
0009
00
01
10
— — — —
000
0010
00
01
11
— — — —
000
0011
00
01
12
— — — —
000
0012
00
01
13
— — — —
000
0013
00
01
14
— — — —
000
0014
00
01
15
— — — —
000
0015
00
01
16
— — — —
000
0016
00
01
17
— — — —
000
0017
00
01
18
— — — —
000
0018
00
01
NEXT
PREVIOUS
RETURN
00653
MACRO STATUS
MAC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
 
 
STATUS
RUN
IDLE
HOLD
IDLE
RUN
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
 
 
STEP
01
09
23
00
00
00
00
00
00
00
00
00
00
00
00
00
 
 
MAC
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
 
 
STATUS
HOLD
RUN
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
IDLE
 
 
STEP
00
22
00
00
00
00
00
00
00
00
00
00
00
00
00
00
 
 
REFRESH
EXIT
20022
PELCO VIDEO SWITCHER
MODEL CM6800
PASSWORD TO MAIN MENU
*******
SCRATCHPAD SEQUENCE
RETURN
MACRO STATUS VIEW
20019