SATO DR300 Manuel D’Utilisation

Page de 18
DR300 Quick Guide  
 
 
 
 
 
Pg 26 
 
 
Serial Interface 
 
Interface Specifications 
 
Protocol 
Ready/Busy 
 
 
(1 item, multi items selectable) 
XON/OFF 
 
 
(1 item, multi items selectable) 
Status 
   (Multi 
item 
only) 
 
Baud rate 
2400, 4800, 9600, 19200 BPS 
Sychronize  
Asynchronous mode 
Maximum 
receive buffer 
capacity 
32K 
 
OK                                              32K
Near full  
occurrence  
                                                                   2Kbytes  remained 
 
Near full  
cancellation 
 
                                                       8Kbytes remained 
Character 
construction 
Data bit   
 
7 or 8 bit 
Start bit   
 
1 bit 
Stop bit   
 
1 or 2 bit 
Parity check 
 
Even, Odd, None 
Data 
Specification 
ASC II (7 bit) 
 
 
Graphic (8 bit) 
Connector 
Printer side DB-25S (Equivalent) 
Cable side DB-25P (Equivalent) 
Cable length less than 5m 
Transmission 
format 
 
Start  b1 b2 b3 
 b4 b5 b6 b7 b8 Stop 
 
Note : b8 is omitted when set to 7 bit data 
Signal level 
High level : +5 ~ +12 V 
Low level : -5 ~ 12 V 
 
 
 
 
 
 
 
 
DR300 Quick Guide   
 
 
 
 
 
Pg 
 
 
Touch Screen / Keypad 
 
Touch screen is connected to printer main body with a cable.