In the following illustration, each binary number corresponds to an error light sequence:
Error conditions
What shows on the four 
indicator lights
Description
Cause and solution
binary 12 (for 0.25 sec),
binary 3 (for 0.25 sec),
repeat continuously.
Serious failure.
The print server is unable 
to recover.
Unrecoverable software error. Call the place where 
you bought your printer.
binary 15 (for 0.25 sec),
binary x (for 0.25 sec),
repeat continuously.
where x could be 0, 1, 2, 3, 
4, 5, 6, 7, 8, or 9
POST error
Power-on self test error. During start-up, a hardware 
failure was detected on the print server. 
• Press the Menu and Test buttons simultaneously 
to reset the print server. 
• If the problem reoccurs, call the place where you 
bought your printer.
binary 9 (for 1 sec)
binary 6 (for 1 sec)
repeat continuously.
The print server is not 
connected to the 
network.
Print a network setup page and look under Status. If 
it shows the printer server is not connected:
• Make sure the Ethernet cable is firmly plugged in.
• Try another wall outlet. 
Test