Lenovo 6434 Manuel D’Utilisation

Page de 110
POST
 
error
 
codes
 
The
 
following
 
table
 
provides
 
an
 
abbreviated
 
list
 
of
 
the
 
error
 
codes
 
that
 
might
 
appear
 
during
 
POST.
 
See
 
the
 
Hardware
 
Maintenance
 
Manual
 
for
 
more
 
information
 
about
 
the
 
POST
 
error
 
codes.
 
To
 
check
 
for
 
updated
 
technical
 
information,
 
complete
 
the
 
following
 
steps.
Note:
  
Changes
 
are
 
made
 
periodically
 
to
 
the
 
Lenovo
 
Web
 
site.
 
The
 
actual
 
procedure
 
might
 
vary
 
slightly
 
from
 
what
 
is
 
described
 
in
 
this
 
document.
 
1.
   
Go
 
to:
 
 
2.
   
Enter
 
your
 
product
 
number
 
(machine
 
type
 
and
 
model
 
number)
 
or
 
select
 
Servers
 
and
 
Storage
 
from
 
the
 
Select
 
your
 
product
 
list.
 
3.
   
Select
 
Servers
 
and
 
Storage
 
from
 
the
 
Brand
 
list.
 
4.
   
From
 
Family
 
list,
 
select
 
ThinkServer
 
TS100
,
 
and
 
click
 
Continue
.
 
5.
   
Click
 
User's
 
guides
 
and
 
manuals
 
for
 
documentation.
 
Table
 
11.
 
Abbreviated
 
list
 
of
 
POST
 
error
 
codes
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Error
 
code
 
Description
 
Action
 
062
 
Three
 
consecutive
 
boot
 
failures
 
using
 
the
 
default
 
configuration.
 
1.
   
Update
 
the
 
system
 
firmware
 
to
 
the
 
latest
 
level
 
(see
 
the
 
Hardware
 
Maintenance
 
Manual.
 
2.
   
(Trained
 
service
 
technician
 
only)
 
Replace
 
the
 
system
 
board.
 
101
 
Tick
 
timer
 
internal
 
interrupt
 
failure.
 
(Trained
 
service
 
technician
 
only)
 
Replace
 
the
 
system
 
board.
 
102
 
Internal
 
timer
 
channel
 
2
 
test
 
failure.
 
(Trained
 
service
 
technician
 
only)
 
Replace
 
the
 
system
 
board.
 
106
 
Diskette
 
controller
 
error.
 
1.
   
Make
 
sure
 
that
 
the
 
Configuration/Setup
 
Utility
 
program
 
correctly
 
reflects
 
the
 
diskette
 
drive
 
information.
 
2.
   
Reseat
 
the
 
diskette
 
drive
 
cable.
 
3.
   
Reseat
 
the
 
diskette
 
drive.
 
4.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Diskette
 
drive
 
cable
 
b.
   
Diskette
 
drive
 
c.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
 
52
 
ThinkServer
 
TS100
 
Types
 
6431,
 
6432,
 
6433,
 
6434:
 
Installation
 
Guide