Lenovo 6434 Manuel D’Utilisation

Page de 110
Table
 
11.
 
Abbreviated
 
list
 
of
 
POST
 
error
 
codes
 
(continued)
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Error
 
code
 
Description
 
Action
 
I9990301
 
Hard
 
disk
 
drive
 
boot
 
sector
 
error.
 
1.
   
Reseat
 
the
 
following
 
components,
 
depending
 
on
 
the
 
server
 
model:
 
v
   
Hot-swap
 
models:
 
a.
   
Hard
 
disk
 
drive
 
b.
   
SAS/SATA
 
controller
v
   
Simple-swap
 
models:
 
a.
   
Hard
 
disk
 
drive
 
b.
   
Hard
 
disk
 
drive
 
cable
2.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
depending
 
on
 
the
 
server
 
model,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
v
   
Hot-swap
 
models:
 
a.
   
Hard
 
disk
 
drive
 
b.
   
Hard
 
disk
 
drive
 
backplane
 
c.
   
SAS/SATA
 
controller
v
   
Simple-swap
 
models:
 
a.
   
Hard
 
disk
 
drive
 
b.
   
Hard
 
disk
 
drive
 
cable
3.
   
(Trained
 
service
 
technician
 
only)
 
Replace
 
the
 
system
 
board.
 
I9990650
 
AC
 
power
 
has
 
been
 
restored.
 
1.
   
Reseat
 
the
 
power
 
cords.
 
2.
   
Check
 
for
 
interruption
 
of
 
the
 
external
 
power.
 
3.
   
Replace
 
the
 
power
 
cords.
  
Troubleshooting
 
tables
 
Use
 
the
 
troubleshooting
 
tables
 
to
 
find
 
solutions
 
to
 
problems
 
that
 
have
 
identifiable
 
symptoms.
 
See
 
the
 
Hardware
 
Maintenance
 
Manual
 
for
 
more
 
detailed
 
troubleshooting
 
information.
 
If
 
you
 
cannot
 
find
 
a
 
problem
 
in
 
these
 
tables,
 
run
 
the
 
diagnostic
 
programs
 
(see
 
“Running
 
the
 
diagnostic
 
programs”
 
in
 
the
 
Hardware
 
Maintenance
 
Manual).
 
If
 
you
 
have
 
just
 
added
 
new
 
software
 
or
 
a
 
new
 
optional
 
device
 
and
 
the
 
server
 
is
 
not
 
working,
 
complete
 
the
 
following
 
steps
 
before
 
you
 
use
 
the
 
troubleshooting
 
tables:
 
1.
   
Check
 
the
 
system-board
 
LEDs
 
or
 
the
 
LEDs
 
on
 
the
 
front
 
panel
 
(see
 
 
2.
   
Remove
 
the
 
software
 
or
 
device
 
that
 
you
 
just
 
added.
 
3.
   
Run
 
the
 
diagnostic
 
tests
 
to
 
determine
 
whether
 
the
 
server
 
is
 
running
 
correctly.
 
 
62
 
ThinkServer
 
TS100
 
Types
 
6431,
 
6432,
 
6433,
 
6434:
 
Installation
 