Lenovo 6431 Manuel D’Utilisation

Page de 110
Microprocessor
 
problems
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
The
 
server
 
emits
 
a
 
continuous
 
beep
 
during
 
POST,
 
indicating
 
that
 
the
 
startup
 
(boot)
 
microprocessor
 
is
 
not
 
working
 
correctly.
 
1.
   
Make
 
sure
 
that
 
the
 
microprocessor
 
is
 
supported
 
on
 
this
 
server.
 
2.
   
(Trained
 
service
 
technician
 
only)
 
Make
 
sure
 
that
 
the
 
microprocessor
 
is
 
seated
 
correctly.
 
3.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
(Trained
 
service
 
technician
 
only)
 
Microprocessor
 
b.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
  
Monitor
 
problems
 
Some
 
Lenovo
 
monitors
 
have
 
their
 
own
 
self-tests.
 
If
 
you
 
suspect
 
a
 
problem
 
with
 
your
 
monitor,
 
see
 
the
 
information
 
that
 
comes
 
with
 
the
 
monitor
 
for
 
instructions
 
for
 
testing
 
and
 
adjusting
 
the
 
monitor.
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
Testing
 
the
 
monitor
 
1.
   
Make
 
sure
 
that
 
the
 
monitor
 
cables
 
are
 
firmly
 
connected.
 
2.
   
Try
 
using
 
a
 
different
 
monitor
 
on
 
the
 
server,
 
or
 
try
 
using
 
the
 
monitor
 
that
 
is
 
being
 
tested
 
on
 
a
 
different
 
server.
 
3.
   
Run
 
the
 
diagnostic
 
programs.
 
If
 
the
 
monitor
 
passes
 
the
 
diagnostic
 
programs,
 
the
 
problem
 
might
 
be
 
a
 
video
 
device
 
driver.
 
4.
   
Reseat
 
the
 
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine
 
(if
 
one
 
is
 
installed).
 
5.
   
Replace
 
the
 
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine
 
(if
 
one
 
is
 
installed).
 
6.
   
(Trained
 
service
 
technician
 
only)
 
Replace
 
the
 
system
 
board.
 
The
 
screen
 
is
 
blank.
 
1.
   
Make
 
sure
 
that:
 
v
   
The
 
server
 
is
 
turned
 
on.
 
If
 
there
 
is
 
no
 
power
 
to
 
the
 
server,
 
see
 
v
   
The
 
monitor
 
cables
 
are
 
connected
 
correctly.
 
v
   
The
 
monitor
 
is
 
turned
 
on
 
and
 
the
 
brightness
 
and
 
contrast
 
controls
 
are
 
adjusted
 
correctly.
 
v
   
A
 
single
 
beep
 
sounds
 
when
 
the
 
server
 
is
 
turned
 
on,
 
indicating
 
the
 
successful
 
completion
 
of
 
POST..
2.
   
Make
 
sure
 
that
 
the
 
correct
 
server
 
is
 
controlling
 
the
 
monitor,
 
if
 
applicable.
 
3.
   
Make
 
sure
 
that
 
damaged
 
BIOS
 
code
 
is
 
not
 
affecting
 
the
 
video;
 
see
 
“Recovering
 
from
 
a
 
BIOS
 
update
 
failure”
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
.
 
4.
   
See
 
“Solving
 
undetermined
 
problems”
 
in
 
the
 
Hardware
 
Maintenance
 
Manual.
 
 
68
 
ThinkServer
 
TS100
 
Types
 
6431,
 
6432,
 
6433,
 
6434:
 
Installation
 
Guide