Performance Test
This test checks the performance of your hard disk by
determining the data transfer rate and track-to-track seek time
based on the transfer size, the seek count, and the amount of
data transferred.
The program measures the data transfer rate in kilobytes per
second. It reads 64KB of data 15 times and counts the number of
timer ticks using this formula:
Transfer rate = (64KB 
15 
18.2) /# timer ticks
The program measures track-to-track seek time in milliseconds
using this formula:
Seek time = (# timer ticks 
1000) / 18.2 
200
(The number of seeks is 200.)
A higher data transfer rate and a lower seek time indicate better
disk performance.
Seek Test
This test checks the seek capability of the hard disk on the
specified range of cylinders and heads. The program performs a
series of sequential seeks followed by random seeks and reports
any errors.
Read/Verify Test
This test checks the read and verify capability of the hard disk
on the specified range of cylinders and heads. The program
performs both sequential and random read and verify operations
and reports any errors.
C- 18