IBM 6867 Manuel D’Utilisation

Page de 362
     
 
 
Specifications Type 6866
Feature
Description
Size
Depth:
606 mm (23.9 inches)
Height: 440 mm (17.3 inches)
Width:
216 mm (8.5 inches)
Weight
Weight:  29.5 kg (65 lb)
7
Environment
Air temperature:
 - System on: 10° to 35°C
(50° to 95°F)
 - System off: 10° to 50°C
(50° to 122°F)
Humidity:
 - System on: 8% to 80%
 - System off: 8% to 80%
Maximum altitude: 3048 m (10,000 ft)
Heat Output
Approximate heat output in BTUs per
hour:
 - Minimum: 340 BTU (100 watts)
 - Maximum: 2385 BTU (700 watts)
8
Electrical Input
Sine-wave input (47 to 63 Hz) required.
Low range input voltage:
 - Minimum: 90 V ac
 - Maximum: 137 V ac
High range input voltage:
 - Minimum: 180 V ac
 - Maximum: 265 V ac
Input kVA (approximately):
 - Maximum (as shipped): 1.50 kVA
Airflow
Approximately 0.56 cubic
meters/minute (20 CFM)
Acoustical
Noise Emission
Values
Average sound pressure levels:
At operator position:
 - 41 dB operating
 - 34 dB idle
At bystander position (1 meter):
 - 34 dB operating
 - 29 dB idle
Declared (upper limit) sound power
levels:
 - 5.3 bels operating
 - 4.7 bels idle
7
Maximum configuration weight depends on options installed.
Figures above are a system fully populated with options.
8
Maximum power and heat specifications are based on the
490-watt maximum capacity of the system power supply.
9
For additional information, see the 
ISO Supplier's Declaration
available from IBM.
   
IntelliStation - 6866
143