GE GFK-2251 Manuel D’Utilisation

Page de 62
 
 
A-4 
Panel C Industrial Computer Hardware User's Manual
 
 
May 2003 
GFK-2251 
A
 
  
 
Nonincendive Field Wiring (Control Drawing #DR00) 
1
USB Port PL6
USB Port PL6
USB Port PL10
Ethernet Port
Keyboard Port
Mouse Port
Panel C
Associated Nonincendive
Field Wiring Apparatus
Hazardous (Classified) Location Class I,
Division 2 Groups A, B, C, and D
Non-hazardous Area
 
Notes: 
1. Nonincendive 
Circuit 
Parameters: 
Panel C Industrial Computer 
Vmax = 5VDC 
Voc = 5 VDC 
Imax = 500mA 
Isc = 500mA 
Ci = 34.2µF 
Ca = 1000µF 
Li = 0mH 
La = 5mH 
2.  Selected Associated Nonincendive Field Wiring Apparatus must satisfy the 
following requirements: 
Associated Nonincendive 
Field Wiring Apparatus 
 Panel 
Industrial Computer 
 Voc 
≤ 
Vmax 
 Isc 
≤ 
Imax 
 C 
≥ 
Ci + C cable 
 
La   
≥ 
Ci + C cable  
 
Vmax   
≥ 
Voc 
 Imax 
 
≥ 
Isc 
 
Ci + Ccable  
≤ 
Ca 
 
Li + Lcable  
≤ 
La 
3.  If the electrical parameters of the cable are unknown, the following values may be 
used: 
Capacitance – 60 pF/ft 
Inductive – 0.20 µH/ft 
4.  Nonincendive Field Wiring must be installed in accordance with Article 501.4(B)(3) 
of the National Electrical Code ANSI/NFPA 70.