Emerson AXP1406 Manuel D’Utilisation

Page de 148
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records
Power Configuration
56
   
2.4.3
Power Configuration
The following table describes the power configuration for the Active SAM.
2.4.4
Active SAM1000 Sensor Overview
The following table lists the discrete and analog sensors that reside on the Active SAM. The 
information in this section supports the SAM on both the AXP1406 and AXP1600 shelves. The 
AXP1600 FRU and sensor data is highlighted and/or marked for ease of use.
Rows that are highlighted in blue provide information for the additional sensors on the 
SAM1000 for the AXP1600.
Table 2-24 SAM1000 Active Power Configuration
Item
Value
Meaning
Dynamic power reconfiguration support
No
Possibility to change FRU power consumption 
without switching it off, according to 
AdvancedTCA
Dynamic power configuration
No
Are the power draw levels fixed or these may vary 
if additional components are hot inserted or 
onboard components’ power consumption is 
changing dynamically
Number of power draw levels
1
The amount of possible power levels, normally 1
Early power draw levels, Watt
5
Complete early power consumption including 
IPMC
Steady state power draw levels, Watt
5
Complete steady power consumption including 
IPMC
Transition from Early to Steady levels, 
sec
0
How long does board consumes early power. 
Early power is normally bigger than steady
Table 2-25 Active SAM1000 Sensor Overview
Sensor 
No.
Sensor Name
Type of 
Measurement
What does it 
measure?
Sensor 
Type
Availability
0
FRU  0 
HOT_SWAP
Status
State of FRU
Discrete
Always
2
FRU  1 
HOT_SWAP
Status
State of FRU
Discrete
Always
3
FRU  2 
HOT_SWAP
Status
State of FRU
Discrete
Always
4
FRU  3 
HOT_SWAP
Status
State of FRU
Discrete
Always
5
FRU  4 
HOT_SWAP
Status
State of FRU
Discrete
Always
6
FRU  5 
HOT_SWAP
Status
State of FRU
Discrete
Always