Emerson AXP1406 Manuel D’Utilisation

Page de 148
Active SAM1000 Analog Sensors
FRU Information and Sensor Data Records
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
63
   
Hysteresis support
No
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable and Settable 
threshold mask (bytes 19, 20)
0x02, 0x00
Lower Critical Threshold is 
Readable
Reading Type
Unsigned
Lower critical threshold
0x23
1190 RPM
Table 2-30 Sensor No. 145 (0x91) FT 3 Fan 1
Feature
Raw Value/Description
Interpreted Value
Sensor Name
FT 3 Fan 1
Device
Sensor Type
0x04
Fan Speed
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x1E
Cooling Unit
Entity Instance
0x62
Rearm mode
Auto
Hysteresis support
No
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable and Settable 
threshold mask (bytes 19, 20)
0x02, 0x00
Lower Critical Threshold is 
Readable
Reading Type
Unsigned
Lower critical threshold
0x23
1190 RPM
Table 2-31 Sensor No. 146 (0x92) FT 3 Fan 2
Raw Value/Description
Feature
Interpreted Value
Sensor Name
FT 3 Fan 2
Device
Sensor Type
0x04
Fan Speed
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x1E
Cooling Unit
Entity Instance
0x62
Rearm mode
Auto
Table 2-29 Sensor No. 144 (0x90) FT2 Fan 2 (continued)
Feature
Raw Value/Description
Interpreted Value