Emerson AXP1406 Manuel D’Utilisation
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
Active SAM1000 Analog Sensors
FRU Information and Sensor Data Records
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
91
Readable and Settable
threshold mask (bytes 19, 20)
threshold mask (bytes 19, 20)
0x36, 0x00
Upper and Lower Critical and
Non-recoverable Thresholds
are Readable
Non-recoverable Thresholds
are Readable
Reading Type
Unsigned
Lower critical and non-
recoverable thresholds
recoverable thresholds
0x73, 0x71
(9.89, 9.718) Volts
Upper critical and non-
recoverable thresholds
recoverable thresholds
0x87, 0xA5
(11.61, 14.19) Volts
Table 2-78 Sensor No. 205 (0xCD) FT 9 Fan 2 12 V, AXP1600
Feature
Raw Value/Description
Interpreted Value
Sensor Name
FT 9 Fan 2 12 V
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x1E
Cooling Unit
Entity Instance
0x68
Rearm mode
Auto
Hysteresis support
No
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable and Settable
threshold mask (bytes 19, 20)
threshold mask (bytes 19, 20)
0x36, 0x00
Upper and Lower Critical and
Non-recoverable Thresholds
are Readable
Non-recoverable Thresholds
are Readable
Reading Type
Unsigned
Lower critical and non-
recoverable thresholds
recoverable thresholds
0x50, 0x4c
(6.88, 6.536) Volts
Upper critical and non-
recoverable thresholds
recoverable thresholds
0x9F, 0xA0
(13.674, 13.76) Volts
Table 2-79 Sensor No. 206 (0xCE) FT 9 Fan 2 VBias, AXP1600
Feature
Raw Value/Description
Interpreted Value
Sensor Name
FT 9 Fan 2 VBias
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Table 2-77 Sensor No. 204 (0xCC) FT 9 Fan 1 VBias, AXP1600 (continued)
Feature
Raw Value/Description
Interpreted Value