Emerson AXP1600 Manuel D’Utilisation

Page de 148
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records
Power Entry Module Sensor Overview
126
   
2.5.4
Power Entry Module Sensor Overview
The following table lists all IPMI sensors available on the Power Entry Module. 
2.5.5
Power Entry Module Analog Sensors
The analog sensors available on the PEM can be divided into the following four categories:
z
z
z
Table 2-134 IPMI Sensors on the PEM
Sensor 
No.
Sensor Name
Type of 
Measurement
What does it 
measure?
Sensor 
Type
Availability
0
Hot Swap
Status
State of FRU
Discrete
Always
1
IPMB Physical
Status
State of IPMB link
Discrete
Always
2
+3.3 V
Voltage
Analog
Always
3
+8 V Backup Out
Voltage
Analog
Always
4
+12 V Backplane
Voltage
Analog
Always
5
CB 1
Status
Circuit Breaker fuse 
state
OEM-
reserved
Always
6
CB 2
Status
Circuit Breaker fuse 
state
OEM-
reserved
Always
7
CB 3
Status
Circuit Breaker fuse 
state
OEM-
reserved
Always
8
CB 4
Status
Circuit Breaker fuse 
state
OEM-
reserved
Always
9
CB 5
Status
Circuit Breaker fuse 
state
OEM-
reserved
Always
10
DS75 Temp
Temperature
Analog
Always
11
+48.0 V FEED
Voltage
Analog
Always
12
+7.5 V PEM
Voltage
Analog
Always
13
+8 V PEM Feed 2
Voltage
Analog
Always
14
+12 V Current
Current
Analog
Always
15
+8 V PEM Feed 1
Voltage
Analog
Always