Emerson AXP1600 Manuel D’Utilisation

Page de 148
Emerson and Pigeon Point OEM Commands
Supported IPMI Commands
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
23
   
This command requests a SAM switchover.
This command instructs the SAM to transition a FRU to the M0 (not installed) state.
Table 1-16 Shelf Manager Switchover (Cmd = 0x02)
Byte
Data field
Request data
1
Pigeon Point Systems IANA Enterprise number, LSB first 
2
0x0A
3
0x40
0x00
4
Flags
0x00 Switchover, but do not reboot the active Shelf Manager
0x01 Switchover, and reboot the active Shelf Manager
Response data
1
Completion Code
2
0x0A
3
0x40
4
0x00
Table 1-17 Set FRU Extracted (Cmd = 0x03)
Byte
Data field
Request data
1
Pigeon Point Systems IANA Enterprise number, LSB first
2
0x0A
3
0x40
0x00
4 IPMB 
address
5
FRU  Id
6
Force option
0x00   Only extract specified FRU if it is in M7 state
0x01   Extract the specified FRU regardless of its current state
Response data
1
Completion Code
2
Pigeon Point Systems IANA Enterprise number, LSB first
3
0x0A
4
0x40
0x00