List 50:  Rectifier Module (PCU) 
Features 
♦  Provides one (1) Model R24-2500, Spec. No. 1R242500, Rectifier 
Module (PCU). 
♦  Refer to Power Data Sheet 
PD588705100/PD588705101/PD588705102/PD588705103/ 
PD588705104 for more information. 
Restrictions 
For use in Spec. No. 588705100, 588705101, 588705102, 588705103, or 588705104 Module Mounting 
Assemblies. 
Ordering Notes 
1)  Order as required. 
 
List 60:  DC-DC Converter Option Interface Component Kit 
Features 
♦  Provides components to add DC-DC Converter capability to one (1) 
8-position Module Mounting Shelf in a Module Mounting Assembly.  
With one (1) List 60 installed, the four middle mounting positions in an 
8-position Module Mounting Shelf in the Module Mounting Assembly 
will accept DC-DC Converters or Rectifier Modules (PCUs). 
♦  Includes cables for connection of converter output to a dual voltage 
bus distribution panel assembly. 
Restrictions 
MUST be factory installed only. 
CANNOT be used in Supplemental Bays. 
Must be used in conjunction with a dual voltage bus distribution panel 
assembly (List 
).  Up to two (2) converter kits 
can be used with a List JA, JB, JC, JD, LB, or LC.  Up to four (4) converter 
kits can be used with a List KA. 
Total rectifier output power available for customer loads is reduced by the input power of each DC-DC 
Converter Module installed. 
Ordering Notes 
1)  Order one (1) List 60 (DC-DC Converter Option Kit) for each 8-position Module Mounting Shelf in which 
DC-DC Converters are required (see restrictions above).  Note that some Module Mounting Assemblies 
consist of multiple 8-position mounting shelves.  The kit permits the middle four (4) positions in an 
8-position Module Mounting Shelf to accept DC-DC Converter Modules or Rectifier Modules (PCUs).  List 
60 is factory installed within the 8-position Module Mounting Shelf.  Multiple List 60 kits will be installed 
starting with bottom 8-position Module Mounting Shelf in the Module Mounting Assembly and working up.  
Note that Supplemental Bays CANNOT have Converter Modules. 
2)  Order up to four (4) converter modules (
) for each List 60 ordered.