3.3
Environmental and Power Requirements
The following environmental and power rewuirements are applicable to the blade.
3.3.1
Environmental Requirements
Table 3-2 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
+5ºC (41ºF) to +40ºC (105ºF) (normal 
operation) according to NEBS Standard GR-
63-CORE
-5ºC to +55ºC (exceptional operation) 
according to NEBS Standard GR-63-CORE
The SAS drives can meet this 
max temperature range of 
non-operating. 
-40ºC (-40ºF) to +70ºC 
(158ºF).
Temp. Change
+/- 0.25ºC/min according to NEBS Standard 
GR-63-CORE
 +/- 0.25ºC/min
Rel. Humidity
5% to 85% non-condensing according to 
Emerson Network Power-internal 
environmental requirements
5% to 95% non-condensing 
according to Emerson 
Network Power-internal 
environmental 
requirements
Altitude
<=3000 m
Maximum weight
4.0 kg
Length x width x 
height
322.3 mm × 280 mm × 29 mm
Vibration
0.1g from 5 to 100 Hz and back to 5 Hz at a 
rate of 0.1 octave/minute
5-20 Hz at 0.01 g
2
/Hz
20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 
m
2
/Sec
3
Random 20-200 Hz at -3 
m/Sec
2
Shock
Half-sine, 11 m/Sec, 30mSec/sec
2
Blade level packaging
Half-sine, 6 mSec at 180 
m/Sec
2