13
The menu operation  includes MAX VOLTAGE SET, MAX POWER SET, 
ROTARY SW SET
,
INITIAL OUT SET
VOLT. SAVE SET, BAUDRATE SET, ADDRESS SET, 
KEY LOCK and 
CLEAR
SAVE DATA
 function. We will describe the details as follows.
2.3.6.1 Set up the maximum output voltage
   When you select the MAX VOLTAGE SET function, the LCD will display as:
                                   MAX VOLT. = 24.00 V
                                   NEW=
2.3.6.2 Set up the maximum output power
                    When you select the MAX POWER SET function, the LCD will display as:
                                   MAX  POWER=108.00W
                                  NEW=
You can set the voltage value by using the number
kaypad or rotating the ROTARY knob. Then confirm
the value by pressing “Enter” button.
You can set the maximum output power  value by
using the number keypad or totating the ROTARY knob.
Then confirm the value by pressing “Enter” button.
 Procedure                 The operation Methods                                                  LCD display
   Step 1
Press “Menu” button                                                           MAX OUT VOLTAGE
                                                                                                              KEY SOUND SET
   Step 2
Enter the password ( Or jump to step 4 if the keyboard     ENTER PASSWORD
                is unlocked)
   Step 3
Press “Enter” button ( it will return to step 2 if your          ENTER PASSWORD
                password is wrong for reentering)                                        1234
   Step 4      The LCD display the menu functions one by one, user        MAX VOLTAGE SET
               can use the UP and DOWN button to change the                 MAX POWER SET
               selecting  each function, Press “Enter” button to execute     ROTARY SW SET
                the  selected function                                                            INITIAL OUT SET
                                                                                                              VOLT. SAVE SET
                                                                                                              BAUDRATE SET
                                                                                                              ADDRESS SET
                                                                                                              KEY LOCK
                                                                                                                   CLEAR SAVE DATA
                                                                                                              EXIT
           It will exit the Menu operation at any procedure by press ESC button