•  Do not modify the AC receptacle in any way.
•  Use only 40-amp or 50-amp fuses. (Replaced by certified 
technician only.)
•  This device does not include an internal Ground Fault 
Circuit  Interrupter  (GFCI).  For  GFCI  protection,  use  a 
Coleman Cable 02822 GFCI outlet.
WARNING: Handling the cord on this product or cords as-
sociated with accessories sold with this product, may expose 
you to lead, a chemical known to the State of California to 
cause cancer and birth defects or other reproductive harm. 
Wash hands after handling.
BEfORE USING PID-760 POWER INvERTER
It is important to know the continuous wattage of the device 
you plan to use with the inverter. The PID-760 must be used 
with devices drawing 760 watts or less. If the wattage is not 
marked on the device, an estimate can be made by multiply-
ing the AC input current (Amps) by the AC voltage (110V). 
Devices like TVs, fans or electric motors require additional 
power to start (commonly known as the “starting or peak 
power”). The PID-760 can supply a momentary surge in 
wattage; however even devices rated less than the maxi-
mum 760 watts can exceed the inverters surge capability 
and cause an automatic overload shutdown.
Make sure the device you are using is compatible with a 
modified sine wave inverter.