Panasonic KW4S Manuel D’Utilisation

Page de 6
Current
Changes
Dedicated protocol and MEWTOCOL
1 to 99  (Note)
Setting start 
→ Protocol switch (dedicated or MEWTOCOL) →
Communication format change
Above content and communication procedure added.
Features added
Change
Communication protocol
Station number setting
Communication format setting
Instruction Manual
Only dedicated protocol
1 to 31
Setting start 
Communication format change
Communication specifications
MEWTOCOL-COM commands
Types
Interface
Protocol
Isolation status
No. of connected units
Transmission distance
Transmission speed (Baud rate)
Transmission
data format
Communication method
Synchronous method
Terminating resistor
Conforming to RS485
Our method
Isolated with internal circuit
99 units*
1,200m
2,400, 4,800, 9,600, 19,200 bps (In each setting mode, settings can be made with front panel keys.)
7-bit/8-bit (In each setting mode, settings can be made with front panel keys.)
Not available/Odd/Even (In each setting mode, settings can be made with front panel keys.)
1 bit (Fix)
Half duplex
Start-stop synchronous method
Approx. 120
Ω (internal)
Note: You must use 1 to 31 when selecting the dedicated protocol (Eco-POWER METER data collection software: AKW4805). 
• Please see the catalog (ARCT1E208E) for details on the Web Datalogger Unit. 
• Please see the “FP series Programmable Controllers” catalog (ARCT1B230E) for details on the FP-e and FP0 PLC. 
RD: Data area read command
WD: Data area write command
MD: Monitor data save and save reset command
MG: Monitor execute command
RT: Status read command
Data length
Parity
Stop bit
The Eco-POWER METER supports five commands.
*We recommend the SI-35 of Lineeye Co., Ltd., for the 
RS485 converter on the PC side. (When using SI-35, 
FP2-CB485 (for FP2-MCU), FP
Σ (COM3 and COM4) or 
FP-e, the maximum number you can connect is 99. When 
using with devices other than these, the maximum 
number will be limited to 31.)
Up to 
99
 Eco-POWER METERs can be connected!
Installation is easy using a CT even 
for the power lines of existing equipment 
and machinery. 
Shrink-wrapping 
machine
 CT
Power line
FP-e
Web
Datalogger
Unit
or
PC used for data
gathering and management
Types and Specifications
MODE
V
A
CHARGE
kWh
S E T
䡺48
䡺1.890
5.5
.217
5.5
.217
87.5
3.445
81.9
3.224
73
2.874
14.5
.571
1) Pin type
2) Screw terminal type
Dimensions
System Diagram
mm
inch
Eco-POWER METER KW4S
KW4S
Eco-POWER METER
Display: Integrated electrical 
energy, Voltage, Current 
and Electricity charge
(
䡺44.5)
(
䡺1.752)
(
䡺44.5)
(
䡺1.752)
Eco-POWER METER   KW4S
01/2005