b (STATUS bit 3): Battery present. 
b=0: Battery not present (empty or disconnected
b=1: Battery present 
 
 
BAT_STATUS (port 252h, read only)nn0cctvv 
This port contains the following read-only battery status information bits. 
 
vv (BAT_STATUS bit 1-0): Battery voltage.  See the section Battery monitor and charger
vv=00: Empty or low 
vv=01: Medium 
vv=10: Full 
vv=11: Disconnected 
 
t (BAT_STATUS bit 2): Battery temperature, according to the battery temperature sensor input.  
When using the PV-1075 NiMH battery module, the sensor should be disconnected, and this bit 
always reports battery too hot
t=0: Battery temperature OK, charger enabled 
t=1: Battery too hot, charger disabled 
 
cc (BAT_STATUS bit 4-3): Charger status. 
cc=00: Charger off.  When using the PV-1075, the charger is always off. 
cc=01: Reserved 
cc=10: Charger on, trickle charging 
cc=11: Charger on, fast charging 
 
nn (BAT_STATUS bit 7-6): Battery type.  With the current firmware, the only possible value is 01. 
nn=00: Reserved 
nn=01: Lead-Acid, or PV-1075 NiMH battery module 
nn=10: Reserved 
nn=11: Reserved 
 
 
RS232_STATUS (port 253h, read only)uuuu0000 
This port contains the following read-only status bits.  They reflect the status of the pins in the 
RS232 connector, whether input from the CPU, or output by the PV-5127.  All four signals are 
active high, i.e. 1=signal active, 0=signal inactive.  Note that RTS (UPS_active) has no function, 
apart from being readable in this port. 
RS232_STATUS bit 4: CD (Lobat).  Output from the PV-5127. 
RS232_STATUS bit 5: CTS (Mainsfail). Output from the PV-5127. 
RS232_STATUS bit 6: RTS (UPS_active). Input into the PV-5127. 
RS232_STATUS bit 7: DTR (Shutdown). Input into the PV-5127. 
 
 
SHUTDOWN (port 254h, read/write)
This port holds the current state of the Softoff state machine.  Please see the section ATX and Softoff 
state machines.  Possible values are: