10
Installing / Connecting the Power Supply
To get your Power Supply up and running, follow these hookup and checkout
procedures.
1.
Mount the power supply
The Power Supply is designed to be free standing, truss mounted, or rack
mounted.
The power supply comes with a mounting bracket which hooks over the pipe or
truss of your lighting rig and is then locked into place with a thumb screw. If you
have selected this mounting method, connect the power supply's safety cable by
clipping it around the pipe or truss.
The power supply can also be mounted into a 19" rack using the optional rack
mount kit. The rack mount kit will accommodate two power supplies side by side.
2.
Connect the device to the power supply
Connect the device to the power supply using a 4-pin Wybron Power/Data cable.
Refer to the HEAD-FEET RESTRICTION section of the manual for details of the
length of cable runs.
Note: The Wybron Power/Data Cable has been specially designed to minimize
voltage drop -- use only Wybron supplied cable.
3.
Connect the Power Supply to AC power
Plug the AC cord into a non-dimmed power circuit. The power supply
automatically accommodates 100 – 240V ~ 50/60 Hz.
Caution:  Do not power the power supply from a dimmed circuit.
Severe damage will result and is not covered by product warranty.
Power at the power supply is indicated by the red LED which can be viewed from
the stage.