Anton/Bauer DUAL 2722 Manuel D’Utilisation

Page de 15
 
 
Three Stage Charging Methodology 
In general, the DUAL 2722 will deliver a three stage charge routine to each battery. 
1.  Stage One will deliver a high rate charge matched to the capabilities of the 
battery (typically a one or two hour rate, depending on battery type).  During this 
stage, six separate cutoff methods are in operation, simultaneously, ensuring the 
fastest, safest charge for that battery: 
TCO - Temperature cutoff which stops the Stage one charge precisely when 
a temperature indicative of full charge is reached; 
Dt/dT - A microprocessor based algorithm which measures a rise in 
temperature over a specific time, very accurately indicating full charge.  This 
method is also the recommended method for charging Ni-MH technology; 
-
- A method to determine the end of stage one charging by identifying a 
characteristic “reverse slope” of a Ni-Cd cell.  Since this characteristic can 
be disguised by the age, temperature and the number of the cells in a battery, 
it can never be employed alone; 
CCO - This method requires the identification of the particular battery size 
(capacity) and chemistry, an exclusive Anton/Bauer Logic Series feature.  
The charger determines the maximum charge time for the particular battery 
and uses this information to ensure that overcharge conditions are avoided. 
FUL - This determination is made when a fully charged DIGITAL battery is 
returned to a charger within specified parameters of time, temperature, and 
battery voltage.  The DIGITAL battery communicates its fully charged 
condition and the charger confirms the parameters and immediately indicates a 
fully charged condition, without additional verification. 
TEMPERATURE COMPENSATED VCO – For HyTRON series of 
batteries.  Optimizes VCO cutoff to operate only within certain temperature 
parameters. 
In addition, a voltage limiting constant current Stage One routine address the critical 
parameters of DIONIC batteries. 
2.  Stage Two charging is a BALANCING or “stabilizing” mode which calculates 
each battery pack type to offset any imbalance of the battery’s cells, created by 
unequal self discharge or any capacity mismatch of the individual cells in the 
pack.  This stage can vary in duration from zero to as much as 16 hours, 
depending on the condition of the battery.  The Stage Two charge for DIONIC 
batteries reduces current automatically as the battery charges maintaining the 
lithium ion cells at a safe voltage level.  A battery will typically leave Stage Two 
in 2-4 hours under average operating conditions. 
3.  Stage Three charging is the Anton/Bauer exclusive Lifesaver maintenance mode.  
This patented pulse routine keeps batteries fully charged, free from self-discharge 
- indefinitely - without damaging heat associated with a so-called “trickle charge”.  
The Stage Three programming for DIONIC monitors the self discharge of the 
battery, providing charge only when the battery self discharges to about 95% of 
its capacity.   
4.  NOTE: Batteries may be kept on a charger until ready for use.  The Lifesaver 
mode will keep them 100% charged.