ADC DS1C Manuel D’Utilisation

Page de 4
10/06 • 101298AE 
Cat 3 DS1/DS1C/DS2 T
ransport System Cable
Category 3 DS1/DS1C/DS2 Transport System Cable
22 AWG STC, Dual Shield, Riser (600C Equiv.)
3
 w w w . a d c . c o m   •   + 1 - 9 5 2 - 9 3 8 - 8 0 8 0   •   1 - 8 0 0 - 3 6 6 - 3 8 9 1
Specifications
CONSTRUCTION CHARACTERISTICS
 Conductors: 
22 AWG solid tinned copper
 
Insulation: 
Polyolefin with lead-free PVC skin
 
Insulation diameter: 
1.24 mm (.049") nominal 2 pair and up
 
 
 
1.34 mm (.053") nominal 1 pair
 
Pairing: 
8.2 twists/meter (2.5 twists/foot) minimum
 
Shielding: Dual 
aluminum/polyester
 
Drain wire: 
22 AWG solid tinned copper
 
Color-coding: Standard 
telephony, 
bandmarked 
 
Rip cord: Non-hygroscopic 
and 
non-wicking
 
Jacket: 
Lead-free flame retardant PVC
 
Jacket Thickness: 
0.76 mm (.030") nominal
ELECTRICAL CHARACTERISTICS
 
Conductor DC resistance (maximum): 5.9Ω/100m (18.0Ω/1000') @ 20° C (68° F)
 
Resistance unbalance (maximum): 5%
 
Insulation resistance: 164mΩ/100m (500mΩ/1000') @ 20° C (68° F)
 
Mutual capacitance:  
4.9nF/100m (15.0 pF/ft) nominal @ 1 kHz
 
Characteristic impedance: 
100 ± 15 Ohms @ 1 MHz
 
Crosstalk: 
43 dB @ .772 MHz
 
 
 
40 dB @ 1.575 MHz
 
 
 
32 dB @ 3.156 MHz
 Temperature 
rating: 
60° C (140° F)
 
Voltage rating: 300 
VDC
Signal
Frequency
(MHz)
Bit Rate
(dB/1000')
(dB/100m)
DS1
.772
1.544
4.2
1.4 
DS1C
1.575
3.152
5.7
1.9
DS2
3.156
6.312
8.4
2.8
Nominal Attenuation:
Compliances:
• UL Subject 444/CSA C22.2 No. 214
• (UL)-C(UL) Type CMR/CMG
• ICEA S-90-661
•  Telcordia Technical Audit Report AU-885 Compliance Testing to GR-137-CORE
• Telcordia GR-499 DSX-1 Pulse Wave Shape Compliance at 650 feet
• Two to four-pair, TIA/EIA-568-B.2 Category 3 Horizontal Cable