ADC Radiator II Fascicule

Page de 2
Spec 
Sheet
Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously 
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may 
verify  product  specifications  by  contacting  our  headquarters  office  in  Minneapolis.  ADC  Telecommunications,  Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features 
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
106823AE  8/08  Revision  ©  2008, 2005, 2004  ADC Telecommunications, Inc.  All Rights Reserved
The Radiator II Below Ground HDSLx 8-Slot Repeater Housing is designed to withstand hostile 
conditions, improve thermodynamic performance and reliability of the outside plant electronics in  
50 percent less manhole space than traditional enclosures. It includes a 30-foot, 100-pair air core 
screened, dual armor cable stub.
ceNtRAL OFFIce
eLectRONIcS
cUStOMeR pReMISeS
eLectRONIcS
OSp
Repeaters
Repeaters
RADIAtOR
OSp
RADIAtOR
Specifications
Housing Construction, Lid:  
Non-corrosive 18-gauge seamless, 316 stainless steel, painted white
Capacity:  
 Supports 8 single or a maximum of 6 double wide HDSL, HDSL4, 
G.SHDSL, T1, ISDN and DDS repeaters
Ambient Temperature Range:
–40˚F to +149˚F (–40˚C to +65˚C)
Relative Humidity:  
100% when pressurized
Pressurization:  
12 psi maximum – pressure relief valve
Security:  
V-band may be secured with a padlock
Dimensions:  
Diameter 12.5”, housing and mounting bracket together 14.25” high
Weight (without modules/cable stub):  Approximately 28 lbs.
Mounting:  
Backboard or underground rack mount
Lightning Protection:  
Three-element gas tube
Safety Standards Compliance: 
Equipment tested and verified to comply with the following standards:
  GR 63-CORE: 
Network Equipment-Building System (NEBS) Requirements 
 
GR 487-CORE: 
Generic Requirements for Electronic Equipment Cabinets 
 
GR 950-CORE:
Generic Requirements for Optical Network Unit (ONU) Closures
  TR-TSY-000056: 
Repeater Housings for T1, T1C, T1D, and T1G Carrier Systems
  FCC Part 15: 
Electrical Safety
  Binational Standard: 
 UL-60950/CSA C22.2 No. 950-95: Safety of Information  
Technology Equipment
O r d e r i n g   I n f o r m a t i o n
Description
  Catalog Number 
Radiator II 8-Slot Below Ground HDSLx Repeater Housing 
  30’ air core stub, pressurized
  RAD-BA30-8