Cabletron Systems DLE32-MA Manuel D’Utilisation

Page de 202
Chapter 4: Troubleshooting
4-4
DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide
4.2
DELTX-UI LED
The optional DELTX-UI has one LED labeled 10/100. The 10/100 LED 
together with the receive LED allows the user to determine the link status 
and the operating speed of the Fast Ethernet Interface Module. The 
10/100 LED and the Receive (RX) LED are shown in Figure 4-2. 
Table 4-2 and Table 4-3 provide a functional description of the 
DELTX-UI LED when the RX LED is on or off, respectively.
TX
Off
Port enabled, and no 
activity.
Should flash green every 2 
seconds indicating BPDUs 
being sent if STA is enabled 
and there is a valid link. If STA 
is enabled, and the LED does 
not flash green, contact your 
DIGITAL representative.
Green
Flashing. Indicates 
activity. Rate indicates 
data rate.
No action.
Amber
Blinking. Port in 
standby, link.
Port may be disabled due to 
Spanning Tree.
Red
Flashing. Indicates 
collision rate. 
No action.
Solid. Diagnostic 
Failure. 
Contact your DIGITAL 
representative for assistance.
Table 4-1
LANVIEW LEDs (Continued)
LED
Color
State