Setting the NVRAM Switch
SEHI100TX User’s Guide
6-5
6.4
SETTING THE NVRAM SWITCH
The SEHI uses NVRAM (Non-Volatile Random Access Memory) to store 
user-entered parameters such as IP address and Community Names. To 
reset these parameters to the factory defaults, refer to Figure 6-2 and 
perform the following steps:
1. With the power ON and using a non-metallic tool, move the NVRAM 
switch to the UP position.
2. Press the RESET switch located on the front panel.
3. Wait until the unit boots (approximately 12 seconds).
4. Return the NVRAM switch to the DOWN position.
Figure 6-2
NVRAM Switch Location
To prevent the possibility of electrical shock, do not remove the 
chassis cover to access the NVRAM switch, and use only a 
non-metallic tool when moving the NVRAM switch.
!
C AUT IO N
Failure to return the NVRAM switch to the DOWN position will 
result in loss of user-entered parameters upon power shutdown 
and restart. The SEHI will clear NVRAM if the unit is restarted 
with the switch in the UP position.
Rear of Chassis
NVRAM Switch located behind grating
1511_02