TROUBLESHOOTING
5-7
5.3  VIEWING POWER UP DIAGNOSTIC TESTS
The MicroMMAC-T runs from BootPROM comprehensive booting and 
diagnostic tests of the device whenever it has been started or reset. You can 
view a chronicle of the tests and any error condition messages they 
produce by connecting your terminal to the COM 2 port of the 
MicroMMAC-T. BootPROM loads the test image into Flash at the 
completion of the test, which lasts approximately two minutes.
NOTE: The LCD displays the following message whenever the POWER 
UP DIAGNOSTIC test is running: “Cabletron Test in Progress.” See 
Section 5.2 for information about LCDs.
The testing process generates information and displays it on your terminal. 
The only time you can issue commands controlling the display of the 
information is when an error condition has been discovered. 
Figure 5-2 shows the opening test information sequence of the POWER 
UP DIAGNOSTIC screen depicting an error condition message with 
response options that are discussed below. 
Figure 5-2.  POWER UP DIAGNOSTIC screen
Responding to Error Messages
Error messages provide you with three response options:
continue 
POWER UP DIAGNOSTIC
 
  register tests
  memory tests
  SCC COM 1 tests
  SCC COM 2 tests
  T.R. adapter tests
CABLETRON Systems, Incorporated
P.O.Box 5005
Rochester, NH 03866-5005
Error: xxxxxx (Error message)
Do you wish to continue, retry, or loop (c, r, or l)?
MicroMMAC-T Diagnostic/Boot Display