Kingston Technology KNE16WG Manuel D’Utilisation

Page de 32
Appendix B    Cabling Guidelines 
17 
EtheRx User’s Guide - Rev. B00 
Kingston Technology Company 
Appendix B    Cabling Guidelines 
 
Cable Type 
When connecting network cables, the following table shows appropriate 
networking guidelines associated with each cable type. 
 
Ethernet Standard: 
10BASE5 
10BASE2 
10BASE-T 
Cable Type: 
RG-11 RG-58A/U 
or 
RG-58C/U 
UTP 
26 - 22 
AWG 
Max. Segment 
Length: 
500M 
(1640ft) 
185M 
(600ft) 
100M 
(328ft) 
Max. Number of 
Nodes per Segment: 
 
100 
 
30 
 
1024 
Connector: 
15-pin D-Sub 
BNC 
RJ-45 
Network Topology: 
Linear Bus 
Linear Bus 
Star 
Table B-1  Network Cable Guidelines 
UTP Cable Wiring 
10BASE-T unshielded twisted-pair cables can be wired as "Straight-Through" 
or, in some cases, "Crossover" depending on the application.  For workstations 
connected to a hub, use "Straight-Through' wiring illustrated in Table B-2.  In 
some instances, you may want to use "Crossover" wiring illustrated below in 
Table B-3. 
 "Straight-Through" 
Crossover” 
 
Cable Wiring 
Cable Wiring 
1 (TRX +)
2 (TRX -)
3 (RCV +)
6 (RCV -)
4, 5, 7, 8
1 (TRX +)
2 (TRX -)
3 (RCV +)
6 (RCV -)
Not Used
Pin Number
Pin Number
1 (TRX +)
2 (TRX -)
3 (RCV +)
6 (RCV -)
4, 5, 7, 8
3 (RCV +)
6 (RCV -)
1 (TRX +)
2 (TRX -)
Not Used
Pin Number
Pin Number
 
Table B-2.  Straight-Through Wiring 