Chapter 2      Cabling and Troubleshooting the CSS
Connecting the Chassis to Ground
2-24
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-06
Attaching the Grounding Cable
The following procedure describes how to attach:
The grounding lug to the grounding cable
The grounding cable to the chassis
Warning
When you install or replace the unit, the ground connection must always be 
made first and disconnected last. 
1.
Power off the chassis by setting the power switch (or switches) to the O (off) 
position.
2.
Strip the covering from the end of the grounding wire (
). The 
amount of covering to be stripped varies depending on the type of lug you 
plan to attach to the wire.
1
Crimping tool
Must fit diameter of grounding 
lugs. Cisco Systems 
recommends that you use a 
crimping tool recommended by 
the lug manufacturer.
2
M5 screws with captive, locking 
washers
Included in accessory kit 
shipped with the CSS.
Table 2-8
Tools and Supplies (continued)
Quantity
Description
Comments
Lug
Strip Length
Panduit no. LCD6-10A-L 
(supplied in accessory kit)
13/16 inch (2 cm)
Panduit no. LCC6-10A-L 
(long barrel)
1 1/16 inch (2.7 cm)
Thomas & Betts no. 
256-30695-1183(*4*)
3/4 inch (1.9 cm)
Burndy no. YA6CL2TC10
7/8 inch (2.2 cm)