Nortel Networks CVX 600 Manuel D’Utilisation

Page de 168
Replacing Modules and Filler Panels
296-1011-202 Rel. 5.0, Doc. Rev. 02.01
3-11
Replacing CVX 600 Components
Replacing the SCC-SM
In a redundant configuration, when you replace the primary SCC-SM, the 
secondary SCC-SM automatically copies the system software and configuration 
files from its flash memory card. Before replacing the primary SCC-SM, ensure 
that the secondary SCC-SM flash memory cards are in the PCMCIA slots.
If you have only one SCC-SM (a non-redundant configuration), you will need to 
shut down the CVX switch to replace the SCC-SM.
Reference
See the manual CVX Multi-Service Access Switch Configuration Guide for 
information about editing and managing configuration files.
Warning: 
You must use software Release 5.0 or later when using an 
Optical SCC-II-SM. Use of older versions will corrupt the SCC-SM, 
requiring the return of the module to Nortel for reprogramming. Do not 
copy earlier versions of software to a flash memory card used in an 
Optical SCC-II-SM.
Warning: 
When you remove the primary SCC-SM, a system reset 
occurs. This disconnects all calls that are in progress and temporarily 
suspends system services until the secondary SCC-SM goes online.