Nortel Networks CVX 600 Manuel D’Utilisation

Page de 168
Connecting Network Cables
2-10
296-1011-202 Rel. 5.0, Doc. Rev. 02.01 
CVX 600 Hardware Installation Guide
Connecting to E1 Interfaces
The E1-DAC-LTM provides 12 or 24 E1 ports and one port for connecting to an 
external clocking device. To connect E1 cables to the E1 ports, and to connect the 
E1-DAC-LTM to an external clocking device, follow this step:  
Step
Action
1
Plug the connectors into the receptacles.
Note: 
Using shielded cabling is an electromagnetic interference (EMI) 
requirement for CVX 600 E1 network configurations.
Note: 
For UK installations using 75 ohm E1 coax, a balun is needed to 
connect to the 120 ohm impedance of the CVX switch. Nortel does not 
recommend a specific balun panel for this application.
Connect to the 
telephone network.
CVX-0243A
Connect to the 
external clocking 
device (optional).
E 112
Cloc
k
12
11
10
9
8
7
6
5
4
3
2
1
E 1 x 24
Cloc
k
12
9
8
5
4
1
24
21
20
17
16
13
12 E1 ports
24 E1 ports
Connect to the 
external clocking 
device (optional).