Nortel Networks CVX 600 Manuel D’Utilisation
Connecting Equipment to the Console Port
296-1011-202 Rel. 5.0, Doc. Rev. 02.01
2-39
Chassis Connections
Connecting a Terminal Server
A terminal server provides remote access to multiple CVX switches through serial
ports connected to the console port of the SCC-RLTMs. A terminal server also
allows the addressing of both SCCs when a CVX switch is using two Optical
SCC-II-LTMs, each with its own console port.
ports connected to the console port of the SCC-RLTMs. A terminal server also
allows the addressing of both SCCs when a CVX switch is using two Optical
SCC-II-LTMs, each with its own console port.
Sample Hardware Arrangement for CVX Switches
CVX-0141C
to Console port
for slot 9
for slot 9
AC PM
AC PM
Fans
1
2
3
4
SEC
PRI
CVX-6oo
BIP
BIP
Filler
System
Po
w
e
r
Good
F
a
iled
Redun
Ether
n
et
HSSI
1
3
2
1
Reset
PCMCIA
1
2
System
Po
we
r
Goo
d
F
a
iled
R
edun
Ether
n
et
HSSI
1
3
2
1
Reset
PCMCIA
1
2
DS1
Y
ello
w Red
1
2
3
4
5
6
7
8
9
10
11
12
Po
w
e
r
Goo
d
F
a
iled
Red
un
Modem
ISDN
Po
w
e
r
Goo
d
F
ailed
Redun
P
ow
e
r
Goo
d
F
a
iled
Red
un
PDU 2
PDU 1
ESD
Jack
O
I
O
I
SCC
SCC
1
2
4
3
5
7
9
8
6
10
13
14
11
12
15
16
17
18
CVX 18oo
ESD
Jack
Jack
Filler
System
Power
Good
Failed
Redun
Ethernet
HSSI
1
3
2
1
Reset
PCMCIA
1
1
2
System
Power
Good
Failed
Redun
Ethernet
HSSI
1
3
2
1
Reset
PCMCIA
1
1
2
DS1
Yellow Red
1
2
3
4
5
6
7
8
9
10
11
12
Power
Good
Failed
Redun
Modem
ISDN
Power
Good
Failed
Redun
Power
Good
Failed
Redun
Fans
Filler
Modem
ISDN
Power
Good
Failed
Redun
Power
Good
Failed
Redun
Filler
Modem
Power
Good
Failed
Redun
Filler
Modem
ISDN
Power
Good
Failed
Redun
Power
Good
Failed
Redun
Filler
Filler
Filler
Modem
Power
Good
Failed
Redun
Slots 9 & 10 for System Controller
1
2
4
3
5
7
9
8
6
10
13
14
11
12
15
16
17
18
CVX 18oo
ESD
Jack
Jack
Filler
System
Power
Good
Failed
Redun
Ethernet
HSSI
1
3
2
1
Reset
PCMCIA
1
1
2
System
Power
Good
Failed
Redun
Ethernet
HSSI
1
3
2
1
Reset
PCMCIA
1
1
2
DS1
Yellow Red
1
2
3
4
5
6
7
8
9
10
11
12
Power
Good
Failed
Redun
Modem
ISDN
Power
Good
Failed
Redun
Power
Good
Failed
Redun
Fans
Filler
Modem
ISDN
Power
Good
Failed
Redun
Power
Good
Failed
Redun
Filler
Modem
Power
Good
Failed
Redun
Filler
Modem
ISDN
Power
Good
Failed
Redun
Power
Good
Failed
Redun
Filler
Filler
Filler
Modem
Power
Good
Failed
Redun
Slots 9 & 10 for System Controller
Terminal
Server
(such as Annex 2000)
to Console port
for slot 10 ***
for slot 10 ***
to Console port for RLTM in slots 9/10
to Console port for RLTM in slots 9/10
Ethernet
Modem
CVX 1800
CVX 1800
CVX 600
*** The connection to the console port for slot 10 is only needed if connecting to the Optical SCC-II-LTM.