Checking the LEDs
296-1011-202 Rel. 5.0, Doc. Rev. 02.01
2-51
Chassis Connections
Optical DAC
The following figure shows the LEDs on the Optical DAC-SM: 
LEDs on the Optical DAC-SM
The following table describes the LEDs on the Optical DAC-SM: 
LED
State
Meaning
Power
Off Power 
off
On (green)
Power on
Good
On (green)
Successful system boot: no errors 
detected
Off
No power: failure detected or on standby
Flashing green
Code loading during system boot
Fail
Off No 
power
On (red)
Failure detected
Redun
Off
No power or no redundancy
On (green)
A working redundant configuration
LOF
Off
Normal
On (orange)
The SONET/SDH framing bytes for A1 or 
A2 are wrong or corrupted.
LOS
Off
Normal
On (orange)
The designated port has a loss of carrier 
condition, due to a faulty connection with 
an SC connector on the receive side or a 
physical break in the fiber.
Note: 
There are no LEDs on the Optical DAC-LTMs.