Q-Logic SN0135524-00 Manuel D’Utilisation

Page de 320
Cisco MDS 9000 Series Switches
Timeout Values
P
AGE
 100
QL
OGIC
 S
WITCH
 I
NTEROPERABILITY
 G
UIDE
 
V
ERSION
 1.0, M
ARCH
 2003
 
Timeout Values
As per FC-SW-2 Fibre Channel standards, set all switches to the following timeout values (TOV) 
in order to successfully establish an E-port connection:
R_A_TOV = 10 seconds
E_D_TOV = 2 seconds
This section provides the steps to change these values.
Cisco Device Manager
ATTENTION!! The following steps take the switch offline; therefore, do not perform them on a 
switch being managed in-band.
1. Start Cisco Device Manager. The Device Manager dialog box displays.
2. From the Device Manager dialog box FC menu, select Timers/Policies.