McDATA Sphereon 4500 Switch
Integration Checklist
The following steps must be completed to successfully merge McDATA and QLogic fabrics. The 
remainder of this section provides detailed instructions and examples.
ATTENTION!!
Backup the current configuration prior to performing the following steps so that the 
configuration is available if something goes wrong.
Disruptions in the fabric can occur as a result of performing the following steps. Therefore, 
it is recommended that these changes be done during down time or off-peak hours.
Verify that the correct version of switch firmware is installed on each switch 
Ensure that each switch has a unique Domain ID and that it falls within the proper range 
Set all switches to the appropriate timeout values 
Ensure that all Zone set and Zone names are unique and conform to ANSI T11 standards 
.
Ensure that all zone members are specified by WWPN 
.
Ensure that all McDATA switches are configured for Open Fabric Interoperability mode 
.
Verify that the fabrics have successfully merged 
Configuration Limitations
When merging McDATA and QLogic fabrics, a maximum of 31 interconnected switches per fabric 
can be configured. Otherwise, all features are fully supported and comply with industry standards.