QLogic CLI
NOTE:
Use the CLI commands when the QLogic SANbox Manager GUI is not available. The 
procedures are the same for the QLogic SANbox2-8, SANbox2-16, and SANbox2-64.
Login: admin
Password: xxxxxxxx
SANbox2 #> show config switch
Use the above command to verify that R_A_TOV is set to 10000 and E_D_TOV is set to 2000. If 
these timeout values are not correct, continue with this section. If the settings are correct, no 
changes need to be made; proceed with the next appropriate section.
SANbox2 #> admin start
SANbox2 (admin) #> config edit
SANbox2 (admin-config) #> set config switch
The following options display:
AdminState (1=Online, 2=Offline, 3=Diagnostics) [Online]
BroadcastEnabled (True / False) [True]
InbandEnabled (True / False) [True]
DefaultDomainID (decimal value, 1-239) [1]
DomainIDLock (True / False) [True]
SymbolicName (string, max=32 chars) [QLogic SANbox2-64]
R_T_TOV (decimal value, 1-1000 msec) [100]
R_A_TOV (decimal value, 100-100000 msec) [9000]
10000
E_D_TOV (decimal value, 10-20000 msec) [1000]
2000
FS_TOV (decimal value, 100-100000 msec) [5000]
DS_TOV (decimal value, 100-100000 msec) [5000]
PrincipalPriority (decimal value, 1-255) [254]
ConfigDescription (string, max=64 chars) [Default Config]
SANbox2 (admin-config) #> config save
SANbox2 (admin) #> config activate
The configuration will be activated.
Please confirm (y/n): [n] y
Principal Switch Configuration
Brocade switches and QLogic switches negotiate for principal switch automatically. Therefore, 
there are no steps to take.