Q-Logic SANBOX2-8C Manuel D’Utilisation
B – Command Line Interface
Show Command
59042-00 A
B-41
FBusy
Number of times the switch sent a P_BSY
because Class 2 frame could not be
delivered within ED_TOV time. Number of
class 2 and class 3 fabric busy (F_BSY)
frames generated by this port in response
to incoming frames. This usually indicates
a busy condition on the fabric or N_port
that is preventing delivery of this frame.
because Class 2 frame could not be
delivered within ED_TOV time. Number of
class 2 and class 3 fabric busy (F_BSY)
frames generated by this port in response
to incoming frames. This usually indicates
a busy condition on the fabric or N_port
that is preventing delivery of this frame.
Flowerrors
Received a frame when there were no
available credits.
available credits.
FReject
Number of frames from devices that were
rejected.
rejected.
InvalidCRC
Invalid CRC detected.
InvalidDestAddr
Invalid destination address detected.
LIP ALPD ALPS
Number of F7, AL_PS LIPs, or AL_PD
(vendor specific) resets, performed.
(vendor specific) resets, performed.
LIPF7ALPS
This LIP is used to reinitialize the loop. An
L_port, identified by AL_PS, may have
noticed a performance degradation and is
trying to restore the loop.
L_port, identified by AL_PS, may have
noticed a performance degradation and is
trying to restore the loop.
LIPF8ALPS
This LIP denotes a loop failure detected by
the L_port identified by AL_PS.
the L_port identified by AL_PS.
LIPF7F7
A loop initialization primitive frame used to
acquire a valid AL_PA.
acquire a valid AL_PA.
LIPF8F7
A loop initialization primitive frame used to
indicate that a loop failure has been
detected at the receiver.
indicate that a loop failure has been
detected at the receiver.
Link Failures
Number of optical link failures detected by
this port. A link failure is a loss of
synchronization for a period of time
greater than the value of R_T_TOV or by
loss of signal while not in the offline state.
A loss of signal causes the switch to
attempt to re-establish the link. If the link is
not re-established by the time specified by
R_T_TOV, a link failure is counted. A link
reset is performed after a link failure.
this port. A link failure is a loss of
synchronization for a period of time
greater than the value of R_T_TOV or by
loss of signal while not in the offline state.
A loss of signal causes the switch to
attempt to re-establish the link. If the link is
not re-established by the time specified by
R_T_TOV, a link failure is counted. A link
reset is performed after a link failure.
Login
Time when user logged in.
Table B-11. Show Port Parameters (Continued)
Entry
Description