Q-Logic 5000 Manuel D’Utilisation

Page de 130
5 – Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
5-8
59096-04  A
S
5.2.2.1
E_Port Isolation
A Logged-In LED error indication is often the result of E_Port isolation. E_Port 
isolation can be caused by the following:
„
Security failure
„
FL_Port is connected to another switch
„
Conflicting domain IDs
„
Conflicting timeout values
„
Conflicting zone membership between active zone sets
Review the event browser and do the following to diagnose and correct an 
isolated E_Port:
1.
Does the event browser show an alarm about an invalid attach on the 
affected port?
„
Yes - Review the ISL group in the active security set to ensure that the 
membership includes the necessary ports and that the secrets on all 
switches are correct.
„
No - Continue.
2.
Does the event browser show a repeating alarm about an unsupported 
E_Port command on the affected port?
„
Yes - The port is configured as an FL_Port and connected to another 
switch. Correct the port connection or the port type.
„
No - Continue.
3.
Display the fabric domain IDs using the Show Domains command. Are all 
domain IDs in the fabric unique?
„
Yes - Continue.
„
No - Correct the domain IDs on the offending switches using the Set 
Config Switch command. Reset the port. If the condition remains, 
continue.