Q-Logic 5000 Manuel D’Utilisation

Page de 130
2 – General Description
Chassis Controls and LEDs
2-2
59096-04  A
S
2.1
Chassis Controls and LEDs
The Maintenance button shown in 
 is the only chassis control and is 
used to reset a switch or to recover a disabled switch. The chassis LEDs provide 
information about the switch’s operational status. These LEDS include the Input 
Power LED, Heartbeat LED, and the System Fault LED. To apply power to the 
switch, plug the power cord into the switch AC power receptacle and into a 100– 
240 VAC power source.
Figure 2-2.  Chassis Controls and LEDS
2.1.1
Maintenance Button
The Maintenance button is a dual-function momentary switch on the front panel. 
Its purpose is to reset the switch or to place the switch in maintenance mode. 
Maintenance mode sets the IP address to 10.0.0.1 and provides access to the 
switch for maintenance purposes when flash memory or the resident configuration 
file is corrupted. Refer to 
for more information about using maintenance mode.
2.1.1.1
Resetting a Switch
To reset the switch, use a pointed tool to momentarily press and release (less than 
2 seconds) the Maintenance button. The switch will respond as follows:
1.
All the chassis LEDs will illuminate except the System Fault LED.
2.
After approximately 1 minute, the power-on self test (POST) begins, 
extinguishing the Heartbeat LED.
3.
When the POST is complete, the Input Power LED is illuminated and the 
Heartbeat LED is flashing once per second.
L
A L
A L
A L
A
L
A L
A L
A L
0
1
2
3
4
5
6
7
AC Power 
Receptacle
Maintenance 
Button
Chassis LEDS