Q-Logic 59047-09 C Manuel D’Utilisation

Page de 264
5 – Fibre Alliance MIB Objects
Related Traps
5-102
59047-09  C
S
connUnitSensorStatusChange (1.3.6.1.3.94.0.5)
The overall status of the connectivity unit has changed. The recommended 
severity level (for filtering) is “alert”. Sent whenever any of the following 
notifications occur:
Chassis.PsBadAlarm 
Chassis.PsOkAlarm 
Chassis.FanBadAlarm
Chassis.FanOkAlarm 
Blade.OverheatAlarm
Blade.OverwarmAlarm 
Variables: { connUnitSensorStatus } 
connUnitPortStatusChange (1.3.6.1.3.94.0.6)
The overall status of the connectivity unit has changed. The recommended 
severity level (for filtering) is “alert”. Sent whenever a UserPort.StateChange or 
UserPort.OperChange event occurs.
connUnitSensorStatusChange
Power supply bad alarm
Power supply OK alarm
Fan bad alarm
Fan OK alarm
Overheat alarm
Overwarm alarm
Temperature OK alarm
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
 connUnitEventTrap
SNMP config change
Switch config change
System config change
Topology change
Zoning change
Zoning merge failure
NameServer change
Generic alarm
Generic event
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_critical
eventSeverity_info
eventSeverity_critical
eventSeverity_warning
Table 5-30. Filter Trap Levels
Trap Type
Cause
Filter Level