1–General Description
Chassis Controls and LEDs
59265-02  B
1-3
Heartbeat LED (Green)
The Heartbeat LED indicates the status of the internal switch processor and the 
results of the power-on self test (POST). Following a normal power-up, the 
Heartbeat LED blinks approximately once per second to indicate that the switch 
passed the POST and that the internal switch processor is running. In 
maintenance mode, the Heartbeat LED remains lit. Refer to 
 for more information about Heartbeat LED blink patterns.
System Fault LED (Amber)
The System Fault LED lights up to indicate that a fault exists in the switch 
firmware or hardware. Fault conditions include POST errors, over-temperature 
conditions, and power supply malfunctions. The Heartbeat LED shows a blink 
code for POST errors and over temperature conditions. For more information, 
refer to 
.
Maintenance Button
The Maintenance button, shown in 
, is a dual-function momentary 
switch on the front panel. Press the maintenance button to reset the switch, or to 
place the switch in maintenance mode. Maintenance mode sets the IP address to 
10.0.0.1 and provides access to the switch for maintenance purposes when flash 
memory or the resident configuration file has been corrupted. For more 
information, see 
Resetting a Switch
To reset the switch, use a pointed tool to press and hold the Maintenance button 
for less than two seconds. The switch responds as follows:
1.
All the chassis LEDs light up except the System Fault LED.
2.
After approximately one minute, the POST begins, extinguishing the 
Heartbeat LED.
3.
When the POST is complete, the Input Power LED lights up, and the 
Heartbeat LED flashes once per second.
Placing the Switch in Maintenance Mode
To place the switch in maintenance mode:
1.
Isolate the switch from the fabric.
2.
Using a pointed tool, press and hold the Maintenance button for a few 
seconds until only the Heartbeat LED is lit. Hold the maintenance button 
until the Heartbeat LED goes out, and then release the button. The 
Heartbeat LED remains lit while the switch is in maintenance mode.
To exit maintenance mode, and return to normal operation, press the 
Maintenance button momentarily.