Q-Logic 5800V Manuel D’Utilisation

Page de 134
4–Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
59265-02  B
4-9
4.
Compare the RA_TOV and ED_TOV timeout values for all switches in the 
fabric using the Show Config Switch command, or click the Switch tab and 
Advanced icon in QuickTools. Is each timeout value the same on every 
switch?
Yes—Continue.
No—Correct the timeout values on the offending switches using the 
Set Config Switch CLI. Reset the port. If the condition remains, 
continue.
5.
Display the active zone set on each switch using the Zoning Active 
command, or click the Active Zoneset tab in QuickTools. Compare the zone 
membership between the two active zone sets. Are they the same?
Yes—Contact your authorized maintenance provider.
No—Deactivate one of the active zone sets, or edit the conflicting 
zones so that their membership is the same, and then reset the port. If 
the condition remains, contact your authorized maintenance provider.
6.
Is the port connected to a switch that supports connection to a TR_Port of an 
QLogic 5800V Series Fibre Channel Switch?
Yes—Configure the port as a TR_Port and map the local and remote 
fabric devices.
No—Contact your authorized maintenance provider.
                                                                                           
NOTE:
E_Port isolation can be caused by merging two fabrics whose 
active zone sets have two zones with the same name, but 
different membership.