Q-Logic SANBOX2 Manuel D’Utilisation

Page de 252
5 – Fibre Alliance MIB Objects
5-108
59047-03  B
A
 lists the possible trap strings returned for the connUnitEventDescr 
variable.
Table 5-33. connUnitEventDescr Variable Field Descriptions
connUnitEventDescr Variable 
Description
Tag #
The number that identifies the event.
Event #
The event counter.
Chassis
The switch on which the event occurred.
Blade
The I/O blade on which the event 
occurred.
Port
The port on which the event occurred.
TimeDate
The time stamp of the event.
Module
The software module where the event was 
initiated.
Addr
The address in the software module where 
the event was initiated.
Descr
The description of the event.
Table 5-34. connUnitEventDescr Trap List
Trap Type
Filter Level
Notification
connUnitPortStatusChange
eventSeverity_info,
eventSeverity_info,
eventSeverity_critical,
eventSeverity_info
UserPort.ConfigChange,
UserPort.StateChange,
Eport.ConvergeAlarm,
UserPort.OperChange 
connUnitDeletedTrap
eventSeverity_info,
eventSeverity_info,
Fabric.OperChange,
Eport.OperChange
 connUnitStatusChange
eventSeverity_info,
eventSeverity_info,
eventSeverity_critical,
eventSeverity_info
Switch.OperChange,
Switch.StateChange,
Switch.ResetAlarm,
Chassis.OperChange