Netgear M4100-50G Manuel D’Utilisation

Page de 768
Utility Commands
556
ProSafe M4100 and M7100 Managed Switches 
write memory
Use this command to save running configuration changes to NVRAM so that the changes 
you make will persist across a reboot. This command is the same as copy 
system:running config nvram:startup-config
.
Format
write memory
Mode
Simple Network Time Protocol (SNTP) Commands
This section describes the commands you use to automatically configure the system time 
and date by using SNTP.
sntp broadcast client poll-interval
This command sets the poll interval for SNTP broadcast clients in seconds as a power of two 
where <poll-interval> can be a value from 6 to 10.
Default
Format
sntp broadcast client poll-interval <poll-interval>
Mode
no sntp broadcast client poll-interval
This command resets the poll interval for SNTP broadcast client back to the default value.
Format
no sntp broadcast client poll-interval
Mode
{image1 | image2}
unit://<unit>/{image1 | 
image2}
Copy an image from the management node to a given 
node in a Stack. Use the unit parameter to specify the 
node to which the image should be copied. 
{image1 | image2}
unit://*/{image1 | 
image2}
Copy an image from the management node to all of 
the nodes in a Stack.
Privileged EXEC
6
Global Config
Global Config
Source
Destination
Description