Chapter 1– Setting Up And Administering The Switch 
 Chapter 1– Setting Up And Administering The Switch 
 Introduction 
This chapter familiarizes the user with the RuggedCom user interface as well as 
describes the following procedures: 
•  Configuring the IP Address and Subnet Mask 
•  Configuring the Gateway Address 
•  Configuring for DHCP Operation  
•  Configuring the Management Connection Inactivity Timeout   
•  Configuring the number of Telnet Sessions 
•  Configuring TFTP Server Permissions  
 
•  Configuring the SNMP Get Community Name 
•  Configuring the System Identification 
•  Configuring Passwords 
•  Configuring the time and date 
•  Configuring SNTP to keep the time and date correct 
•  Configuring SNMP Management Stations 
The RuggedSwitch™ User Interface 
Using the RS232 Port to Access the User Interface 
Attach a terminal (or PC running terminal emulation software) to the RS232 port 
on the rear of the chassis.  The terminal should be configured for 8 bits, no parity 
operation at 57.6 Kbps.  Hardware and software flow control must be disabled.  
Select a terminal type of VT100.  
Once the terminal is connected, pressing <CR> will prompt for the password to 
be entered.  The switch is shipped with a default administrator password of 
admin”.  Once successfully logged in, the user will be presented with the main 
menu.