RuggedCom M2100 Manuel D’Utilisation

Page de 30
24 
© 
2008 RuggedCom Inc. All rights reserved 
 
Rev106
 
 
5 Technical 
Specifications 
5.1  Power Supply Specifications 
 
Input Range 
Max. Power Consumption
Power Supply 
Type 
Min 
Max 
Fuse 
Rating 
10/100TX 
FE Ports 
Worst Case 
12 – 24 VDC 
10 VDC 
36 VDC 
6.3A(F) 
2
 
24 VDC 
18 VDC 
36 VDC 
5A(F) 
2
 
48 VDC 
36 VDC 
59 VDC 
2A(T)
 2
 
HI (125/250 VDC) 
1
 
HI (110/230 VAC) 
1
 
88 VDC 
85 VAC 
300 VDC 
265 VAC 
2A(T)
 1,2
 
15 W 
30 W 
 
NOTES:   
1.  This is the same power supply for both AC and DC. 
2.  (F) Denotes fast-acting fuse, (T) denotes time-delay fuse 
3.  Power consumption varies based on configuration. 10/100BaseTX ports consume roughly 
1W less than fiber optic ports. 
4.  For continued protection against risk of fire, replace only with same type and rating of fuse. 
 
5.2 Failsafe Relay Specifications 
 
Parameter 
Value (Resistive Load) 
Max Switching Voltage 
240VAC, 125VDC 
Rated Switching Current  2A @ 240VAC 
0.15A @ 125VDC, 2A @ 30VDC 
Max Switching Capacity  150W, 500VA