Chapter 9 - Using Ethernet And RMON Statistics 
Startup Alarm 
The alarm that may be sent after the first measurement period.  If the first sample 
is greater than or equal to the rising threshold and Startup Alarm is equal to 
“rising” or “risingOrFalling”, then a rising alarm will be generated.  If the first is 
less than or equal to the falling threshold and Startup Alarm is equal to “falling” or 
“risingOrFalling”, then a falling alarm will be generated. 
Rising Event 
The index of the RMON Events Table entry that is used when a rising threshold is 
crossed.  If this value is zero or if there is no corresponding entry in the RMON 
Events Table, then no alarm will be generated. 
Falling Event 
The index of the RMON Events Table entry that is used when a falling threshold 
is reached.  If this value is zero or if there is no corresponding entry in the RMON 
Events Table, then no alarm will be generated. 
Owner 
A field describing the person who configured this record and any applicable 
contact information.  The RMON specification recommends that the string always 
start with the word “monitor”.