3com WX3000 Manuel D’Utilisation

Page de 715
 
1-11 
Enabling the System to Test Connected Cable 
You can enable the system to test the cable connected to a specific port. The test result will be returned 
in five minutes. The system can test these attributes of the cable: Receive and transmit directions (RX 
and TX), short circuit/open circuit or not, the length of the faulty cable.  
Follow these steps to enable the system to test connected cables: 
To do… 
Use the command… 
Remarks 
Enter system view  
system-view 
— 
Enter Ethernet port view  
interface interface-type interface-number 
— 
Enable the system to test 
connected cables  
virtual-cable-test 
Required 
 
 
Optical port (including Combo optical port) does not support VCT (virtual-cable-test) function. 
Combo electrical port supports VCT function only when it is in UP condition (using undo shutdown 
command), normal Ethernet electrical port always supports this function. 
 
Configuring the Interval to Perform Statistical Analysis on Port Traffic 
By performing the following configuration, you can set the interval to perform statistical analysis on the 
traffic of a port. 
When you use the display interface interface-type interface-number command to display the 
information of a port, the system performs statistical analysis on the traffic flow passing through the port 
during the specified interval and displays the average rates in the interval. For example, if you set this 
interval to 100 seconds, the displayed information is as follows: 
 Last 100 seconds input:  0 packets/sec 0 bytes/sec 
 Last 100 seconds output:  0 packets/sec 0 bytes/sec 
Follow these steps to set the interval to perform statistical analysis on port traffic: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter Ethernet port view 
interface interface-type 
interface-number
 
— 
Set the interval to perform 
statistical analysis on port traffic 
flow-interval interval 
Optional 
By default, this interval is 300 
seconds.